Calculating hydraulic conductivity from well log pumping test. The test well well 3 fully penetrated an 18ft thick sand and gravel aquifer under nonleaky artesian conditions. These methods are, the nonequilibrium type curve method, the modified nonequilibrium straight line method, the stepdrawdown analysis developed by. Pdf single well test is more common than aquifer test with having observation well, since the advantage of single well test is that the pumping. You will be responsible for the following analysis. A pumping test involves pumping from a test well at a controlled rate and monitoring the flow rate from the well and the drawdown in an array of observation wells at varying radial distances from the test well. The analysis of the hydraulics of wells for the evalu ation of groundwater potentialities by pumping tests falls in the category of groundwater hydrology. Pdf hydrogeologists determine the hydraulic characteristics of waterbearing formations, by conducting pumping tests. A slug test is simple, fast, inexpensive and does not require pumps or complex equipment. For a variable pumping rate they adopted a piecewiselinear approximation. Program pdf this course focuses on the practical application of pumping test theory to developing understandings of groundwater systems. Pumping test analysis with a handheld calculator rayner. Recovery test measurements allow the transmissivity of the aquifer to be calculated, thereby providing an independent check on the results of the pumping test.
Confined aquifer pumping test analysis waterloo hydrogeologic. Pdf analysis and evaluation of pumping test data second. A manual pumping test method is presented, which at a fraction of the cost of a conventional pumping test, measures the specific capacity of ropepump wells. This rise in water level is known as residual drawdown s. A5 summary of results of analysis of pumping test data from. May 10, 2016 see how to do manual and automated type curve fitting jacob straight line analysis of pumping test data from an observation well. Attendees will gain a more understanding about the analysis of pumping tests and the determination of. Standard test method field procedure for instantaneous change in head slug tests for determining hydraulic properties of aquifiers. Guide to conducting pumping tests british columbia. On simulation and analysis of variablerate pumping tests. A pumping test enables us to determine the drawdown y of the water level in the well as a function of the discharge.
The test indicates the permeability of the localized area near the testing site. Pdf performing pumping test data analysis applying cooper. Designed by hydrogeologists for hydrogeologists, aquifertest delivers all the tools needed to accurately interpret data from all types of aquifers in all. Aquifer testing is a common tool that hydrogeologists use to characterize a system of aquifers, aquitards and flow system boundaries. Zhenga abstract the concepts of twoway coordinates and oneway coordinates are used to describe the different characteristics of two key. Theory and analysis methods pumping test analysis methods fixed assumptions theis recovery test confined when the pump is shut down after a pumping test, the water level inside the pumping and observation wells will start to rise. Although pumping test analysis is a mature topic in hydrogeology, the current analysis of temperature measurements in the context of trts is comparatively a new topic and it could benefit from the application of concepts related to pumping tests. Although often interpreted separately, a recovery test is an integral part of any pumping test. From the help menu or click on the toolbar to obtain.
Spreadsheets for the analysis of aquifertest and slugtest data, version 1. Select search from the help menu and click the find tab to search the documentation for help topics. Performing pumping test data analysis applying cooperjacobs. Aquifer tests are performed to evaluate the capacity of an aquifer to meet municipal or industrial.
Pumping test analysis software aqtesolv is the most advanced software for pumping test pump test analysis in confined, leaky confined, unconfined and. Aquifer testing is a common tool that hydrogeologists use to characterize a system of. Pump test analysis the idea of a pump test is to stress the aquifer by pumping or injecting water and to note the drawdown over space and time. In a recent linkedin poll, groundwater professionals overwhelmingly chose aqtesolv as their preferred pumping test analysis software. It has become a common practice nowadays to use computers in the analysis of pumping tests. The composite multiwell analysis indicated the following bestestimate aquifer property values. However, it is recommended to avoid large volume tests during periods of severe drought. Spreadsheets for the analysis of aquifer test and slug test data, version 1. Results of pumping test evaluation and statistical analysis of. Introduction to pumping test analysis national centre for. Buy analysis and evaluation of pumping test data, 2nd revised edition on free shipping on qualified orders. Analysis of data from a correctly executed pumping test can be one of the most reliable methods of determining the mass permeability of. Curve matching pumping test data with the theis type curve. Q pumping rate feet3day note that these units are feet3day, not gpm.
Even so, the test analysis report must address this variation in a scientifically disciplined manner including the impact on the ability of the pumping test to determine the test wells sustainable yield. The response to pumping indicated the well could not sustain aflowi riite of 2gpm. Derivative analysis is a powerful diagnostic technique for the interpretation of data from pumping tests. In order to maximize drawdown in the pumping and observation wells, an aquifer test was started at. Aquifertest is an easytouse software package for analyzing, interpreting and visualizing pumping and slug test data. Constantrate test procedure 47 analysis and interpretation 49 6. The test is made by observing groundwater flow that is produced by known hydraulic. It will teach you very important background information to allow defendable interpretations of aquifer testing data using traditional methods and stateoftheart software. For fractured bedrock and other lowyielding wells, a pumping test should be done during a dry period when water tables are least likely to be affected by temporary rainfall events. Pdf recently, composite analysis ca, which simultaneously analyzes all drawdown data from multiple observation wells, has been applied. Spreadsheets for the analysis of aquifertest and slugtest. Lets consider interpretations of drawdown data with and without derivative analysis. Attendees will gain a more understanding about the analysis of pumping tests and the determination of aquifer hydraulic properties.
Pumping and slug tests 4iii revision 1, december 2006 major changes from the february 1995 tgm the ohio epa technical guidance manual for. Evaluation of methods of pumping test analyses for application to hawaiian aquifers by john a. Estimation of hydraulic conductivity using the slug test. Software for pumping test analysis by hydrosolve, inc. Software for pumping test analysis by hydrosolve, inc what is the best software for pumping test analysis. To convert from gpm, which is used on well logs, to feet3day use the following equation. Hydrologic test analysis results for the 3day constantrate pumping test were limited in this report to a composite multiwell analysis for the pumped well and nearfield wells 299w1540 and 299w1544. The different characteristics of aquifer parameters and their implications on pumping test analysis by j. American society for testing and materials astm pumping test. Even so, the test analysis report must address this variation in a scientifically disciplined manner including the impact on the ability of the pumping. Ground water issue suggested operating procedures for aquifer pumping tests robert s. This document is not intended to be an overview of aquifer test analysis. The software is a curve fitting procedure for analysing fractured rock pumping test data.
For this edition of our book, we seriously considered adding. Pdf analysis of pumping test data for determining unconfined. History the earliest model for interpretation of pumping test data was developed by thiem 1906 adolf and gunther for o constant pumping rate. Overview of the jacob analysis for evaluating constant rate pumping test. This course introduces the basic equations of groundwater flow, the analytical techniques that have been developed to solve these equations, and their practical implementation in pumping test. A stepdrawdown test was completed at well 0181 onjuly 8,2002, using flow rates bf i and 2 gpm. Analysis and evaluation of pumping test data, 2nd revised.
When the diameter of the pipes is chosen, it is possible to calculate the manometric head y for different discharges q. Analysis of pumping test data for determining unconfinedaquifer parameters. Improved characterization of small u for jacob pumping. An aquifer test or a pumping test is conducted to evaluate an aquifer by stimulating the aquifer through constant pumping, and observing the aquifers response in observation wells. Analysis and evaluation of pumping test data hydrology. Tpa includes the following methods to analyse fracturedrock pumping test data.
Test pumping analysis or tpa is a windowsbased software program, developed in delphi. In this note, we generalize the approach of roumboutsos and stewart 1988 to commonly used analytical solutions for pumping test analysis. American society for testing and materials astm pumping test 1. Jun 10, 2015 105105 pumping test reportspumping test reports pumping test reports should include the following. Calculating hydraulic conductivity from well log pumping. These methods are, the nonequilibrium type curve method, the modified nonequilibrium straight line method, the stepdrawdown analysis developed by water survey staff members, and the analysis of an. A4 data from pumping test of kalauao test well on 21061 17. Free pumping test programme university of the free state. The pumping test was performed a minimum of 33 times in three wells over an. This report documents several spreadsheets that have been developed for the analysis of aquifer pumping test and slug test data. Pumping test procedures for water withdrawal applications. This report documents several spreadsheets that have been developed for the analysis of aquiferpumping test and slugtest data.
Improved characterization of small u for jacob pumping test analysis methods by scott c. Analysis and evaluation of pumping test data uga hydrology. Standard guide for selection of aquifer test method in determining hydraulic properties by well techniques. In south africa, the main aim of pumping tests is to estimate what we call sustainable yield of a borehole. Pumping continued for eight hours at a constant rate of 220 gallonsperminute gpm. Technical guidance manual for ground water investigations. The users manual button will display a pdf document of the manual, which requires the adobe. A map, showing the location of the investigateda map, showing the location of the investigated site, pumping and observation wells. The analysis and evaluation of pumping test data is adequately covered by numerous texts on the subject dawson and istok, 1991. All openings to the aquifers must be known and only those.
Nov 14, 2012 derivative analysis is a powerful diagnostic technique for the interpretation of data from pumping tests. Constant rate gridley walton 1962 presented data from a pumping test conducted on july 2, 1953 near gridley, illinois. Make aqtesolv your choice for pumping test analysis software to get a complete package for constant and variablerate pumping tests, recovery tests, sinusoidal tests, singlewell tests, stepdrawdown tests, tests with multiple pumping wells, automatic image well generation, predictive simulation and pumping test design, and more. The different characteristics of aquifer parameters and their. A pumping test is a field experiment in which a well is pumped at a controlled rate and waterlevel response is measured in one or more surrounding observation wells and optionally in the pumped well control well itself. A kind of single well test, which is stepdrawdown test used to determine the efficiency and specific capacity of the well, however in case of single well test it is possible to estimate transmissivity, but the other parameter which is storativity is overestimated, so the aim of this study is to analyze four pumping test data located in. The method requires only sight modifcations to the well and reasonable limitations on well useage prior to testing. Use of the derivative in pumping test analysis can highlight many flow regime features that otherwise may be hard to discover when inspecting drawdown data alone. Recoverytest measurements allow the transmissivity of the aquifer to be calculated, thereby providing an independent check on the results of the pumping test. See how to do manual and automated type curve fitting jacob straight line analysis of pumping test data from an observation well.
1141 1075 1612 111 1201 575 1175 1205 1659 911 1017 1505 1122 511 754 951 455 1579 1275 874 918 760 1001 185 469 544 194 430 1429 185 1028 512 562